zabbix监控DELL iRADC风扇+温度+内存(zabbix模板自行下载)
16lz
2021-04-24
一、准备
1.iDRAC开启SNMP服务
2. 确保开启snmp 和端口(116)
zabbix 服务端通过snmp验证
snmpget -v 2c -c xkeshi ip .1.3.6.1.4.1.674.10892.2.1.1.2.0SNMPv2-SMI::enterprises.674.10892.2.1.1.2.0 = STRING: "iDRAC8"
二、zabbix web配置
1、创建值映射
zabbix web界面 —> 管理 —> 一般 —> 值映射
将根据下列名称进行值映射
DellDracDiskState
1 -> Unknown2 -> Ready3 -> Online4 -> Foreign5 -> Offline6 -> Blocked7 -> Failed8 -> Non-RAID9 -> RemovedDell iDRAC Network Device Connection Status1 -> Connected2 -> DisconnectedDell Open Manage System Status1 -> Other2 -> Unknown3 -> OK4 -> NonCritical5 -> Critical6 -> NonRecoverableDellPowerState1 -> Other2 -> Unknown3 -> Off4 -> OnDell PSU State Settings1 -> Unknown2 -> Online (state disabled)4 -> not Ready8 -> Fan Failure10 -> Online and Fan Failure16 -> On242 -> Online and OKDellRaidLevel1 -> Unknown2 -> RAID-03 -> RAID-14 -> RAID-55 -> RAID-66 -> RAID-107 -> RAID-508 -> RAID-609 -> Concatenated RAID 110 -> Concatenated RAID 5DellRaidVolumeState1 -> Unknown2 -> Online3 -> Failed4 -> DegradedDell_PSU_SensorState1 -> Presence Detected2 -> PS Failure4 -> Predictuve Failure8 -> PS AC lost16 -> AC lost or out of range32 -> AC out of range but still present
2、配置全局变量{$SNMP_COMMUNITY_IDRAC}
zabbix web界面 —> 管理 —> 一般 —> 宏
3、导入模板
模板下载地址:https://github.com/endersonmaia/zabbix-templates/tree/master/dell/idrac
zabbix web界面 —> 配置 —> 模板 —> 导入
Template_Dell_iDRAC_SNMPv2.zbx.xml
4、创建主机
zabbix web界面 —> 配置 —> 主机 —> 创建主机
输入主机地址及SNMP地址和端口,保存
5、利用grafana进行可视化配置
至此,所有操作步骤已经完成,你可以定义不同的图形将所有的监控项进行整合,
©著作权归作者所有:来自51CTO博客作者wx5b99ec814c1ab的原创作品,如需转载,请注明出处,否则将追究法律责任更多相关文章